Commercial fresh air exchanger

Home / Products /

Commercial fresh air exchanger

Fresh air exchange and filtration for commercial building ventilation.

Commercial fresh air exchanger

Overview

The commercial fresh air exchanger provides coordinated outdoor-air supply and indoor-air extraction for ducted commercial ventilation. Incoming and outgoing airstreams pass through a selected recovery arrangement so useful energy can be exchanged before the air is supplied to the occupied zones.

The medium-capacity family described in the catalogue combines two-way ventilation, filtration and energy recovery. Ceiling-mounted and floor-standing arrangements address different plant-space conditions, allowing the equipment location to be coordinated with the wider duct network.

The unit is selected around ventilation duty rather than room area alone. Occupancy, required air quantity, air conditions, duct resistance and operating hours all affect the appropriate model and installation arrangement.

Commercial fresh air exchanger

PRODUCT DETAILS

Product Features

Coordinated two-way ventilation

Dedicated supply and extract paths support the introduction of outdoor air and removal of used indoor air. The intended balance is established through equipment and duct-system selection.

Energy-recovery function

The selected exchange section uses the difference between the two airstreams to recover useful energy. Recovery behaviour depends on the chosen core type and operating conditions.

Filtered incoming air

Filtration treats incoming air before it enters the occupied space. The selected filter arrangement should account for the outdoor environment and the pressure available from the fan.

Installation-form choices

The catalogue describes suspended and floor-standing formats within the medium series. The appropriate form is chosen around the equipment room, service access and duct connection routes.

Commercial duct-system duty

The fan selection is coordinated with the required airflow and external resistance. Filters, ducts, dampers and terminal outlets all contribute to the actual operating point.

Maintenance and acoustic planning

Service access and equipment positioning are important for occupied buildings. The catalogue advises against placing larger medium-series units directly over noise-sensitive meeting or office areas without an appropriate acoustic design.

MODEL DATA

Technical Specifications

Medium high-efficiency recovery ventilators · D ceiling / L floor-standing variants. Catalogue pages 43–44.

Swipe tables horizontally to view all specifications.

Catalogue Performance Models
Model Voltage (V) External pressure (Pa) Airflow (m³/h) Input power (W) Current (A) Weight (kg)
RNXHBQ-D15 380 163 1500 500 1.76 120
RNXHBQ-L15 380 163 1500 500 1.76 130
RNXHBX-D15 380 163 1500 500 1.76 125
RNXHBX-L15 380 163 1500 500 1.76 135
RNXHBQ-D20 380 176 2000 640 2.24 120
RNXHBQ-L20 380 176 2000 640 2.24 138
RNXHBX-D20 380 176 2000 640 2.24 125
RNXHBX-L20 380 176 2000 640 2.24 143
RNXHBQ-D25 380 200 2500 740 2.76 160
RNXHBQ-L25 380 200 2500 740 2.76 175
RNXHBX-D25 380 200 2500 740 2.76 165
RNXHBX-L25 380 200 2500 740 2.76 185
RNXHBQ-D30 380 210 3000 1100 2.9 165
RNXHBQ-L30 380 210 3000 1100 2.9 188
RNXHBX-D30 380 210 3000 1100 2.9 170
RNXHBX-L30 380 210 3000 1100 2.9 198
Recovery and Noise
Model Enthalpy recovery cooling (%) Enthalpy recovery heating (%) Temperature recovery (%) Noise dB(A)
RNXHBQ-D15 66 70 71 52
RNXHBQ-L15 66 70 71 52
RNXHBX-D15 – – 74 52
RNXHBX-L15 – – 74 52
RNXHBQ-D20 62 71 71 56
RNXHBQ-L20 62 71 71 56
RNXHBX-D20 – – 74 56
RNXHBX-L20 – – 74 56
RNXHBQ-D25 61 70 70 60
RNXHBQ-L25 61 70 70 60
RNXHBX-D25 – – 72 60
RNXHBX-L25 – – 72 60
RNXHBQ-D30 60 69 69 61
RNXHBQ-L30 60 69 69 61
RNXHBX-D30 – – 72 61
RNXHBX-L30 – – 72 61

RNXHBQ and RNXHBX are different recovery variants. A dash means enthalpy recovery is not listed for that variant. The catalogue family description spans 1,500–6,000 m³/h; the performance rows reproduced here are the published D15–D30 / L15–L30 ratings. Confirm the exact selected variant.

WHERE IT WORKS

Applications

The catalogue identifies meeting facilities, offices, equipment rooms, restaurants, shops and entertainment premises. Equipment can serve a ventilation zone or room group through a properly selected supply and extract duct arrangement.

Confirm supply and extract quantities, core type, filtration, fan pressure and noise requirements. Dedicated kitchen, contaminated or process exhaust requires its own suitability assessment.

Send Your Requirements →
  • Commercial office and meeting-space ventilation systems.
  • Retail or leisure buildings with predictable operating schedules.
  • Restaurants and shared indoor areas requiring general fresh air.
  • Equipment rooms where the air characteristics suit the selected exchanger.
Meeting Rooms interior with coordinated ventilation and air distribution
Meeting Rooms Fresh-air planning for shared meeting spaces.
Hotel Lobbies interior with coordinated ventilation and air distribution
Hotel Lobbies Ventilation and thermal comfort for shared hospitality spaces.