Modular Desiccant Wheel Dehumidification Unit

घर / उत्पादों /

मॉड्यूलर डिसेकेंट व्हील डीह्यूमिडिफिकेशन यूनिट

एक शुष्कक पहिया और पुनर्जनन वायु सर्किट का उपयोग करके मॉड्यूलर नमी नियंत्रण।

मॉड्यूलर डिसेकेंट व्हील डीह्यूमिडिफिकेशन यूनिट

Overview

The modular desiccant wheel dehumidification unit provides continuous moisture removal for applications where a cooling coil alone is not sufficient. Process air passes through a slowly rotating desiccant medium, which adsorbs water vapour before the drier air leaves the treatment section.

A separate heated regeneration airstream removes the retained moisture from another zone of the wheel and carries it outdoors. As the wheel rotates between the process and regeneration zones, adsorption and regeneration continue as a repeating cycle. This arrangement allows moisture control to be coordinated with the required supply-air temperature.

The catalogue includes basic and combined units, with optional filtration, pre-cooling, post-cooling and mixing sections. Electric or steam regeneration can be selected according to the available utilities and project operating strategy.

Modular Desiccant Wheel Dehumidification Unit

PRODUCT DETAILS

Product Features

Continuous desiccant process

The rotating moisture-adsorbing medium moves between treatment and regeneration zones. This provides ongoing drying instead of relying on a material that must be removed and replaced after every operating cycle.

Separate regeneration circuit

A dedicated fan and heater supply regeneration air to remove moisture from the wheel. The regeneration airflow, heat source and exhaust route are designed together with the process-air duty.

Modular treatment arrangement

Pre-cooling, post-cooling, filtration, fan and mixing sections can be combined around the moisture-control section. This allows the unit to address temperature and humidity as related design requirements.

Choice of regeneration heat

The catalogue lists electric and steam heating options. The appropriate arrangement depends on the site’s utilities, regeneration duty, operating hours and the selected equipment configuration.

Insulated cabinet construction

An aluminium-alloy frame and double-skin insulated panels support the modular assembly. Thermal-bridge control and a sealed wheel arrangement help manage unwanted heat transfer and air bypass.

Optional monitoring and controls

PLC control and selected alarms can support fan, heater and rotor operation. Options include humidity control, rotor-stop or filter alerts, remote operation and monitoring of selected temperatures.

MODEL DATA

Technical Specifications

LF standard desiccant wheel dehumidification series. Catalogue pages 35–36.

Swipe tables horizontally to view all specifications.

Moisture Removal and Regeneration
Model Moisture removal (kg/h) Process airflow (m³/h) Electric regeneration (kW) Steam regeneration (kg/h)
LF-15 12–20 720–2040 18 40
LF-30 20–32 1380–4020 36 70
LF-50 32–60 2280–6660 60 120
LF-80 60–95 3720–10740 96 200
LF-120 95–150 6120–17460 144 300
LF-200 150–230 9720–27900 240 500
LF-250 230–310 12060–34440 300 600
Mechanical and Fan Data
Model Regeneration fan (kW) Wheel speed (rph) L × W × H (mm) Weight (kg)
LF-15 0.37 10–23 1100 × 850 × 1430 220
LF-30 1.1 10–23 1300 × 1100 × 1880 260
LF-50 2.2 10–23 1500 × 1300 × 2130 350
LF-80 3 15–28 1600 × 1520 × 2390 420
LF-120 4 15–28 1800 × 1960 × 2750 550
LF-200 7.5 15–28 2200 × 2150 × 3130 700
LF-250 11 15–28 2400 × 2500 × 3530 900

Catalogue rating basis: process air 20°C and 60% RH; regeneration temperature 120–140°C. Electric and steam entries are alternative regeneration arrangements. Wheel speed is revolutions per hour (rph), as printed. Cabinet dimensions may vary with the project configuration.

WHERE IT WORKS

अनुप्रयोगों

The catalogue identifies electronics production, precision-instrument rooms, museums, libraries, storage and process drying as applications. More demanding low-humidity production requires a model and complete treatment arrangement specifically selected for that duty.

Confirm process airflow, entering conditions, target humidity, regeneration utilities and exhaust routing. Very low dew-point duties require a dedicated selection and should not be assumed from the general product description.

Send Your Requirements →
  • Electronics and industrial production with defined humidity limits.
  • Museums, archives and material stores concerned with moisture exposure.
  • Food, film, wood and other process-drying applications.
  • Specialist dry-room systems designed around a specified humidity or dew point.
Illustration of pharmaceutical production equipment in a bright processing room
Pharmaceutical Production Humidity and air-treatment requirements coordinated with the process.
Illustration of an electronics workshop with rows of assembly benches
Electronics Manufacturing Air-treatment planning for controlled production conditions.

PROJECT INQUIRY

Discuss This Equipment

Tell us about your equipment requirements and installation conditions.

From cleaner air
to a better future.

官网询盘