Centrifugal Air Curtain
A centrifugal-fan air curtain for building entrances and larger openings.
Centrifugal Air Curtain
Overview
The centrifugal air curtain uses a fan-driven discharge to form an air barrier at a building opening. The catalogue describes an external-rotor centrifugal fan arrangement with pressure capability suited to the selected entrance duty and, where specified, an air-heating section.
Heated versions transfer energy from a selected hot-water, steam or electric source into the discharge air. Coil construction is matched to the heat medium, so different thermal arrangements are not interchangeable without a proper equipment selection.
The cabinet can be coordinated with exposed or concealed installation and the intended interior finish. Door dimensions, available heat source, mounting conditions and the required airflow pattern determine the appropriate unit and its position.
PRODUCT DETAILS
Product Features
Centrifugal fan air delivery
The fan arrangement provides the pressure needed for the selected discharge duty. Airflow and pressure are coordinated with the entrance geometry and the resistance of the unit’s treatment sections.
Selected heating arrangement
The catalogue lists hot-water, steam and electric heating possibilities. The available utility, required thermal duty and installation constraints determine the appropriate version.
Heat-medium-matched coil
Copper-tube aluminium-fin or other specified heat-exchanger constructions are selected according to the heating medium and operating conditions. Coil selection is confirmed with the actual supply temperatures or steam duty.
Cabinet finish choices
Painted, electrostatically coated and brushed-stainless cabinet options are described within the range. The selected finish can be coordinated with the room appearance and exposure conditions.
Exposed or concealed installation
Different cabinet arrangements allow the air curtain to work with the entrance design. Clear inlet, discharge and service access remain necessary in either installation form.
Serviceable equipment assembly
Fan, heating and casing access should be maintained after installation. The location should also allow inspection of the selected water, steam or electrical connections.
MODEL DATA
Technical Specifications
FM centrifugal air-curtain family. Catalogue pages 43–44.
Swipe tables horizontally to view all specifications.
| Model | Airflow (m³/h) | Fan power (kW) | Supply (V) | Air speed (m/s) | L × W × H (mm) |
|---|---|---|---|---|---|
| FM-2509 | 3500 | 0.8 | 380 | 11–16 | 950 × 450 × 880 |
| FM-2512 | 5000 | 0.45 × 2 | 380 | 11–16 | 1250 × 450 × 880 |
| FM-2515 | 6000 | 0.55 × 2 | 380 | 11–16 | 1550 × 450 × 880 |
| FM-2518 | 7500 | 0.45 × 3 | 380 | 11–16 | 1850 × 450 × 880 |
| FM-2520 | 8100 | 0.45 × 3 | 380 | 11–16 | 2050 × 450 × 880 |
| FM-2522 | 9000 | 0.55 × 3 | 380 | 11–16 | 2250 × 450 × 880 |
| FM-2525 | 10000 | 0.8 × 3 | 380 | 11–16 | 2550 × 450 × 880 |
| Model | Electric heating (kW) | Hot-water heating (kW) | Cooling / heating variant (kW) |
|---|---|---|---|
| FM-2509 | 30 | 31 | 23 / 31 |
| FM-2512 | 40 | 44 | 33 / 44 |
| FM-2515 | 50 | 53 | 40 / 53 |
| FM-2518 | 60 | 62 | 46 / 62 |
| FM-2520 | 65 | 65 | 48 / 65 |
| FM-2522 | 70 | 70 | 53 / 70 |
| FM-2525 | 90 | 89 | 67 / 89 |
Thermal columns identify alternative configurations. Electric-heating capacity is separate from fan power. The catalogue describes hot-water, steam and electric heating options; confirm heat source, coil materials, inlet conditions and installation clearances for the ordered model.
WHERE IT WORKS
Applications
The catalogue identifies shopping centres, office buildings, hotels, restaurants, workshops and underground garages. Each opening has different exposure and airflow conditions, so equipment is selected against the actual use rather than the building category alone.
Confirm opening dimensions, mounting position, air duty and the available heat medium. Installation and controls should be coordinated with door use, occupant comfort and maintenance access.
Send Your Requirements →- Commercial and hotel entrances with frequent door movement.
- Restaurant or office entry areas requiring a selected air barrier.
- Workshop doorways with a suitable heating utility.
- Garage and service openings assessed for the selected unit.
PROJECT INQUIRY
Discuss This Equipment
Tell us about your equipment requirements and installation conditions.
From cleaner air