Large Standard Series Energy Recovery Ventilator

Home / Products /

Large Standard Series Energy Recovery Ventilator

Larger-format supply and extract air ventilation with energy recovery.

Large Standard Series Energy Recovery Ventilator

Overview

The large standard series energy recovery ventilator is a larger-format supply-and-extract unit for buildings with substantial ventilation demand. It coordinates incoming outdoor air and outgoing room air through the selected recovery arrangement, reducing the additional thermal treatment associated with fresh-air provision.

The catalogue describes a floor-standing installation that can be located in an equipment room or in a suitably protected outdoor location. Separating the larger ventilation equipment from the occupied zone can also help with acoustic planning.

Large-airflow equipment needs a system-level selection. Supply and extract quantities, fan pressure, core type, duct connections and service clearances are coordinated with the installation location and the building’s operating schedule.

Large Standard Series Energy Recovery Ventilator

PRODUCT DETAILS

Product Features

Larger ventilation duties

The standard series addresses air quantities beyond small room-level equipment. Model selection starts with the actual building ventilation requirement and the proposed distribution zones.

Coordinated air exchange

Supply and extract fans provide the two airstreams needed for the selected ventilation and recovery arrangement. Their duty is checked with the resistance of each connected air route.

Selected recovery type

The catalogue distinguishes recovery configurations within the range. Heat-only or total-energy requirements are confirmed for the actual model rather than inferred from the general series name.

Floor-standing equipment format

The cabinet can be arranged within a plant area instead of above an occupied room. Floor loading, handling access and the equipment footprint are included in layout planning.

Acoustic separation

Locating the larger unit in a suitable equipment space helps separate the fan source from occupied areas. The duct and outlet design still need to address noise transmission.

Outdoor protection where needed

The catalogue notes that outdoor installations require additional rain protection and other appropriate measures. Outdoor exposure suitability must be resolved for the complete supplied installation.

MODEL DATA

Technical Specifications

Large Standard Series · RNXHBQ / RNXHBX floor-standing units. Catalogue pages 47–48.

Swipe tables horizontally to view all specifications.

Airflow and Electrical Data
Model Voltage (V) Airflow (m³/h) External pressure (Pa) Power (W) Current (A) Weight (kg)
RNXHBQ-L75 380 7500 290 4400 9.7 285
RNXHBX-L75 380 7500 290 4400 9.7 266
RNXHBQ-L100 380 10000 340 6000 13.04 290
RNXHBX-L100 380 10000 340 6000 13.04 281
RNXHBQ-L150 380 15000 420 11000 24 360
RNXHBX-L150 380 15000 420 11000 24 342
RNXHBQ-L200 380 20000 480 15000 30.4 365
RNXHBX-L200 380 20000 480 15000 30.4 362
Recovery and Noise
Model Enthalpy recovery cooling (%) Enthalpy recovery heating (%) Temperature recovery (%) Noise dB(A)
RNXHBQ-L75 64 69 72 76
RNXHBX-L75 – – 74 76
RNXHBQ-L100 63 69 72 80
RNXHBX-L100 – – 73 80
RNXHBQ-L150 64 67 72 85
RNXHBX-L150 – – 75 85
RNXHBQ-L200 62 68 72 88
RNXHBX-L200 – – 74 88
Main Cabinet Dimensions (mm)
Model suffix L W H
75 1800 850 1700
100 2000 950 1800
150 2200 1250 1900
200 2500 1250 2200

RNXHBQ and RNXHBX have different recovery characteristics; a dash means enthalpy recovery is not listed. The main dimensions apply to the corresponding paired model suffixes. Outdoor placement requires suitable weather protection, and the control enclosure location must follow the installation requirements.

WHERE IT WORKS

Applications

Suitable for larger offices, public buildings, hospitality and commercial ventilation systems using centralized air distribution. It is relevant where a floor-standing unit and substantial supply and extract ducts can be accommodated.

Provide air quantities, indoor and outdoor conditions, recovery preference, duct resistance and equipment-space constraints. Confirm filtration, weather protection and maintenance access for the chosen unit.

Send Your Requirements →
  • Larger commercial buildings with centralized ventilation demand.
  • Hotels and public facilities operating several ventilation zones.
  • Equipment-room installations serving remote occupied areas.
  • Protected outdoor plant arrangements designed for the selected equipment.
Illustration of a high-bay warehouse aisle between tall storage racks
High-Bay Warehouses Air distribution suited to large industrial indoor volumes.
Illustration of a double-height hotel lobby with lounge seating and tall windows
Hotel Lobbies Ventilation and thermal comfort for shared hospitality spaces.

PROJECT INQUIRY

Discuss This Equipment

Tell us about your equipment requirements and installation conditions.

From cleaner air
to a better future.

官网询盘