Коммерческий блок обработки воздуха прямого расширения
Взрывозащищенный блок кондиционирования
Air conditioning equipment configured for the specified hazardous-area requirements.
Взрывозащищенный блок кондиционирования
Overview
The explosion-proof air conditioning unit is a specialist air-treatment product for projects where the surrounding atmosphere requires a defined explosion-protection approach. Its thermal and ventilation duties are selected alongside the electrical, mechanical and control requirements of the particular location.
The catalogue describes direct-expansion and water-system arrangements. A direct-expansion version uses a matched refrigeration source, while a water-system version exchanges heat with the selected building water circuit. Filtration and other treatment stages are coordinated with the process brief.
Protection requirements apply to the complete selected assembly, including relevant fans, electrical components, controls, enclosures and accessories. The equipment designation, documentation and permitted environment must be checked for the actual model; a general product name does not establish suitability for a particular hazardous area.
PRODUCT DETAILS
Product Features
Application-specific protection
The fan, control and electrical arrangements are selected around the site’s identified protection requirements. Ordinary electrical components should not be assumed suitable merely because they are installed inside an air-handling cabinet.
Choice of system arrangement
The catalogue includes direct-expansion and water-based configurations. This allows the thermal treatment concept to be coordinated with the available utilities and the project’s installation constraints.
Protected enclosure design
Selected enclosures and component arrangements address the required protection strategy. Mechanical integrity, joints, cable entries and access details are considered together within the equipment specification.
Surface-temperature consideration
The thermal behaviour of exposed equipment surfaces is part of selection. The chosen assembly needs to be appropriate for the identified atmosphere and the applicable temperature requirements.
Material and sealing options
Corrosion resistance and sealing can be coordinated with the environment. Material selection considers exposure conditions as well as the maintenance and cleaning needs of the installation.
Coordinated controls and accessories
Control devices, switches and other relevant accessories need to be specified consistently with the selected unit. The complete package and its supplied documentation are reviewed before installation.
MODEL DATA
Technical Specifications
Explosion-protected water-system AHU · RNJK-Z catalogue reference. Catalogue pages 29–30.
Swipe tables horizontally to view all specifications.
| Model | Airflow (m³/h) | Listed power (kW) | Total pressure (Pa) | Noise dB(A) | L × W × H (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| RNJK-020Z | 2000 | 1 | 200 | 52 | 2400 × 700 × 750 | 330 |
| RNJK-030Z | 3000 | 1 | 200 | 55 | 2500 × 800 × 900 | 382 |
| RNJK-040Z | 4000 | 1 | 250 | 56 | 2500 × 900 × 900 | 410 |
| RNJK-050Z | 5000 | 2 | 250 | 57 | 2600 × 1000 × 1000 | 480 |
| RNJK-060Z | 6000 | 2 | 250 | 59 | 2600 × 1000 × 1100 | 550 |
| RNJK-070Z | 7000 | 2 | 250 | 60 | 2900 × 1200 × 1200 | 580 |
| RNJK-080Z | 8000 | 3 | 250 | 60 | 2900 × 1200 × 1200 | 600 |
| RNJK-0100Z | 10000 | 4 | 250 | 62 | 3200 × 1200 × 1280 | 630 |
| RNJK-0120Z | 12000 | 4 | 300 | 62 | 3200 × 1320 × 1280 | 672 |
| RNJK-0150Z | 15000 | 6 | 300 | 64 | 3200 × 1400 × 1400 | 720 |
| RNJK-0180Z | 18000 | 6 | 300 | 68 | 3700 × 1600 × 1800 | 970 |
| RNJK-0200Z | 20000 | 8 | 300 | 72 | 3700 × 1750 × 1800 | 990 |
| RNJK-0220Z | 22000 | 9 | 350 | 73 | 3900 × 1800 × 1800 | 1050 |
| RNJK-0250Z | 25000 | 11 | 350 | 75 | 3900 × 1800 × 1800 | 1120 |
| RNJK-0270Z | 27000 | 15 | 500 | 76 | 4200 × 2000 × 1800 | 1260 |
| RNJK-0300Z | 30000 | 19 | 500 | 77 | 4200 × 2300 × 1900 | 1560 |
| RNJK-0350Z | 35000 | 22 | 500 | 77 | 4500 × 2400 × 2200 | 1740 |
| RNJK-0400Z | 40000 | 30 | 500 | 79 | 4600 × 2600 × 2200 | 1920 |
| RNJK-0450Z | 45000 | 30 | 500 | 79 | 4800 × 2800 × 2400 | 2100 |
| RNJK-0500Z | 50000 | 37 | 600 | 81 | 4800 × 3000 × 2400 | 2400 |
| RNJK-0600Z | 60000 | 37 | 600 | 85 | 5100 × 3200 × 2600 | 2740 |
| Model | 4-row cooling / heating (kW) | 6-row cooling / heating (kW) | 8-row cooling / heating (kW) |
|---|---|---|---|
| RNJK-020Z | 13.2 / 17.6 | 19.9 / 26.6 | 26.6 / 35.5 |
| RNJK-030Z | 19.8 / 26.4 | 29.7 / 39.6 | 39.6 / 52.8 |
| RNJK-040Z | 26.4 / 35.2 | 39.6 / 52.8 | 52.8 / 70.4 |
| RNJK-050Z | 33.3 / 44.4 | 49.5 / 66.6 | 66 / 88 |
| RNJK-060Z | 39.6 / 52.8 | 59.9 / 79.2 | 79.2 / 105.6 |
| RNJK-070Z | 46.2 / 61.6 | 69.3 / 92.4 | 92.4 / 123.2 |
| RNJK-080Z | 52.8 / 70.4 | 79.2 / 105.6 | 105.6 / 140.8 |
| RNJK-0100Z | 66.6 / 88.8 | 99.9 / 133.2 | 133.2 / 177.6 |
| RNJK-0120Z | 79.8 / 106.4 | 119.7 / 159.6 | 159.6 / 212.8 |
| RNJK-0150Z | 99.6 / 132.8 | 149.4 / 199.2 | 199.2 / 265 |
| RNJK-0180Z | 120 / 160 | 180 / 240 | 240 / 320 |
| RNJK-0200Z | 133.2 / 177.6 | 199.8 / 266.4 | 256.2 / 290.4 |
| RNJK-0220Z | 146.4 / 195.2 | 219.6 / 292.8 | 292.8 / 390.4 |
| RNJK-0250Z | 166.6 / 222.1 | 249.3 / 332.4 | 332.4 / 443.2 |
| RNJK-0270Z | 180 / 240 | 270 / 360 | 360 / 480 |
| RNJK-0300Z | 199.8 / 266.4 | 299.7 / 399.6 | 399.6 / 532.8 |
| RNJK-0350Z | 233.4 / 311.1 | 350.1 / 466.8 | 466.8 / 622.4 |
| RNJK-0400Z | 266.4 / 355.2 | 399.6 / 532.8 | 532.8 / 711 |
| RNJK-0450Z | 300 / 400 | 450 / 600 | 600 / 800 |
| RNJK-0500Z | 333 / 444 | 499.5 / 666 | 666 / 888 |
| RNJK-0600Z | 399.6 / 532.8 | 599.4 / 799.2 | 799.2 / 1065 |
These are the catalogue’s water-system reference values, not DX-unit ratings. Exact hazardous-area suitability, electrical protection and documentation must be checked for the selected model. Numbers are reproduced as printed, including irregular source entries; the final selection schedule governs.
WHERE IT WORKS
Applications
The catalogue identifies chemical processing, petroleum-related facilities, solvent-handling areas and specialist industrial or laboratory environments. These are project categories for assessment, not a statement that a single unit is suitable for every hazard within them.
Provide the atmosphere classification, substances involved, required protection designation, thermal duty and site conditions. Confirm the selected model’s documentation and approval with the responsible project specialists.
Send Your Requirements →- Chemical and process facilities with a defined atmosphere classification.
- Specified solvent-handling or coating areas.
- Specialist industrial rooms requiring protected equipment selection.
- Laboratory or production projects with documented environmental constraints.