Ceiling-Mounted Heat Recovery Unit

Home / Products /

Ceiling-Mounted Heat Recovery Unit

A ceiling-mounted air handling unit combining fresh air treatment and heat recovery.

Ceiling-Mounted Heat Recovery Unit

Overview

The ceiling-mounted heat recovery unit combines ventilation-air treatment and energy exchange in a suspended air-handling format. It is intended for projects that need both supply and extract functions but cannot allocate the floor space required by a larger plant-room unit.

The selected recovery section transfers useful energy between incoming outdoor air and outgoing air. Additional filter, coil and moisture-treatment sections can be arranged around this function, depending on the selected configuration and the required leaving-air condition.

The catalogue’s suspended recovery air-handler arrangement differs from a simple room fan: fan pressure, thermal duty, air paths and service clearances are selected together. Water connections, condensate disposal and any humidification utilities are included only where the selected treatment stages require them.

Ceiling-Mounted Heat Recovery Unit

PRODUCT DETAILS

Product Features

Suspended equipment arrangement

The cabinet is designed to make use of an overhead service zone. Structural supports, handling access and available ceiling depth must suit the selected unit and its operating weight.

Integrated energy exchange

The recovery function uses the difference between extract and outdoor-air conditions. The actual exchange method and recovery behaviour are confirmed for the selected unit arrangement.

Separate supply and extract duties

The catalogue provides distinct supply and extract fan duties. Both air paths are considered when calculating airflow, duct resistance and the intended ventilation balance.

Optional thermal treatment

Cooling and heating coils can be included in the selected air-treatment arrangement. Their capacity and water conditions are coordinated with the ventilation load and the room requirements.

Filtration and moisture options

Filter stages and any humidification section are chosen for the application. These functions are not assumed to be the same on every ceiling recovery unit.

Serviceable installation planning

The suspended position needs practical access for filters, fans, recovery components and drains. Maintenance openings and clearance should be agreed before the finished ceiling is installed.

MODEL DATA

Technical Specifications

RNJK-R suspended ceiling heat-recovery AHU. Catalogue pages 15–16.

Swipe tables horizontally to view all specifications.

Airflow and Dual-Fan Data
Model Airflow (m³/h) Supply fan (kW) Supply external pressure (Pa) Extract fan (kW) Extract external pressure (Pa) Humidification (kg/h)
RNJK-010R 1000 0.45 150 0.2 180 3
RNJK-013R 1300 0.45 150 0.2 180 3.3
RNJK-015R 1500 0.45 145 0.2 180 4.1
RNJK-018R 1800 0.55 210 0.45 210 5.2
RNJK-020R 2000 0.55 210 0.45 210 5.7
RNJK-024R (2400) 2400 0.55 200 0.45 210 7.2
RNJK-024R (2500) 2500 0.7 290 0.55 274 8.6
RNJK-030R 3000 0.7 260 0.55 250 8.6
RNJK-035R 3500 1.1 210 0.75 270 11
RNJK-040R 4000 1.1 180 0.75 230 12
RNJK-045R 4500 1.5 250 1 270 12
RNJK-050R 5000 1.5 210 1 270 12.6
RNJK-060R 6000 1.8 350 2.2 230 21.9
RNJK-080R 8000 3.4 300 2.2 230 28.5
RNJK-0100R 10000 4 500 3.5 400 28
Main Cabinet Dimensions
Model L × W × H (mm)
RNJK-010R 2020 × 1100 × 615
RNJK-013R 2020 × 1100 × 615
RNJK-015R 2020 × 1100 × 615
RNJK-018R 2215 × 1305 × 615
RNJK-020R 2215 × 1305 × 615
RNJK-024R (2400) 2215 × 1305 × 615
RNJK-024R (2500) 2215 × 1400 × 715
RNJK-030R 2215 × 1400 × 715
RNJK-035R 2300 × 1500 × 715
RNJK-040R 2300 × 1500 × 715
RNJK-045R 2400 × 1600 × 735
RNJK-050R 2400 × 1600 × 735
RNJK-060R 2500 × 1650 × 815
RNJK-080R 2950 × 2150 × 900
RNJK-0100R 2950 × 2150 × 900

Supply and extract fan ratings are separate. Humidification is the catalogue’s configured value, not a requirement for every order. The source prints RNJK-024R for both 2,400 and 2,500 m³/h entries; airflow is appended here to distinguish them without inventing a corrected code. Confirm coil rows and final dimensional drawing.

WHERE IT WORKS

Applications

Suitable for commercial projects requiring a suspended recovery air handler and a defined duct network. The layout is relevant when useful extract air is available and ceiling or overhead service space can accommodate the complete selected assembly.

Confirm air quantities, recovery type, thermal duties, utilities and external static pressure. Review ceiling support, connection routing and maintenance access alongside the unit dimensions.

Send Your Requirements →
  • Offices and shared commercial areas with overhead service zones.
  • Hotel ventilation serving a group of occupied rooms.
  • Public-building fresh-air systems with selected thermal treatment.
  • Refurbishment where floor space is limited but overhead access is practical.
Illustration of a meeting room with a long conference table and wall screen
Meeting Rooms Fresh-air planning for shared meeting spaces.
Illustration of an open-plan office with lounge seating and exposed ceiling services
Open-plan Offices Air distribution for comfortable commercial workspaces.