Small Size High Efficiency Series Energy Recovery Ventilator
Compact energy recovery ventilation for projects with restricted installation space.
Small Size High Efficiency Series Energy Recovery Ventilator
Overview
The small size high efficiency series energy recovery ventilator provides two-way air exchange in a compact ceiling-mounted package. It introduces outdoor air, removes used indoor air and transfers useful energy between the two streams through the selected plate-type recovery core.
The catalogue describes a cross-counterflow exchange arrangement intended to improve recovery while limiting internal air resistance. The series brings ventilation, filtration, energy recovery and bypass functions together in a cabinet suited to smaller ventilation duties.
Compact size is useful only when the complete installation remains workable. The chosen airflow, service clearance and duct connections should fit the room brief and the available ceiling void, with access retained for filter changes and inspection.
PRODUCT DETAILS
Product Features
Compact ventilation package
The series combines supply and extract functions in one cabinet. Its smaller format is intended for projects that need a manageable equipment size without giving up a planned ventilation route.
Cross-counterflow plate exchange
The plate recovery arrangement uses the difference between the two airstreams to transfer useful energy. Actual recovery behaviour depends on air conditions, airflow and the selected model.
Selectable air quantities
The catalogue includes several compact airflow sizes. A model is chosen from occupancy and room use, followed by a check of the fan pressure available for the installed duct system.
Ceiling and orientation flexibility
The series is intended for ceiling installation and includes alternative mounting orientations. The approved orientation is checked against the chosen model’s connections and maintenance requirements.
Noise-conscious construction
The catalogue describes non-metallic components, moulded production and a compact internal structure aimed at lower operating noise. Equipment position, duct layout and outlet selection remain important to the final room result.
Filtration and bypass functions
Air cleaning and bypass are listed alongside recovery within the series. Filter type and the control sequence for seasonal operation are confirmed in the selected configuration.
MODEL DATA
Technical Specifications
Small High-Efficiency Series · RNXHBQ-TF. Catalogue pages 35–36.
Swipe tables horizontally to view all specifications.
| Model | Voltage (V) | External pressure H / M / L (Pa) | Airflow H / M / L (m³/h) | Input power (W) | Current (A) | Weight (kg) |
|---|---|---|---|---|---|---|
| RNXHBQ-D1.5TF | 220 | 75 / 58 / 34 | 150 / 120 / 80 | 60 | 0.5 | 35 |
| RNXHBQ-D2.5TF | 220 | 85 / 70 / 30 | 250 / 200 / 165 | 60 | 0.5 | 39 |
| RNXHBQ-D3.5TF | 220 | 90 / 60 / 36 | 350 / 300 / 200 | 60 | 0.6 | 40 |
| RNXHBQ-D5TF | 220 | 100 / 60 / 30 | 500 / 400 / 300 | 110 | 1.1 | 43 |
| RNXHBQ-D6TF | 220 | 110 / 70 / 30 | 600 / 500 / 400 | 110 | 1.1 | 64 |
| RNXHBQ-D8TF | 220 | 120 / 98 / 60 | 800 / 650 / 500 | 240 | 1.8 | 71 |
| RNXHBQ-10TF | 220 | 125 / 105 / 65 | 1000 / 800 / 600 | 300 | 2.4 | 83 |
| Model | Cooling recovery H / M / L (%) | Heating recovery H / M / L (%) | Temperature recovery H / M / L (%) | Noise H / L, dB(A) |
|---|---|---|---|---|
| RNXHBQ-D1.5TF | 60 / 63 / 67 | 70 / 72 / 74 | 75 / 76 / 77 | 44 / 22 |
| RNXHBQ-D2.5TF | 60 / 63 / 67 | 70 / 72 / 73 | 75 / 76 / 77 | 46 / 22 |
| RNXHBQ-D3.5TF | 64 / 66 / 67 | 68 / 69 / 72 | 73 / 75 / 77 | 49 / 25 |
| RNXHBQ-D5TF | 60 / 62 / 68 | 65 / 67 / 72 | 72 / 75 / 78 | 51 / 25 |
| RNXHBQ-D6TF | 60 / 65 / 64 | 65 / 68 / 70 | 72 / 75 / 77 | 54 / 30 |
| RNXHBQ-D8TF | 62 / 65 / 68 | 70 / 71 / 74 | 73 / 75 / 77 | 56 / 32 |
| RNXHBQ-10TF | 62 / 65 / 68 | 70 / 71 / 74 | 73 / 75 / 77 | 56 / 31 |
| Model | L | L1 | W | W1 | W2 | H | H1 | C | N (Ø) |
|---|---|---|---|---|---|---|---|---|---|
| RNXHBQ-D1.5TF | 860 | 810 | 660 | 710 | 315 | 240 | 88 | 70 | 108 |
| RNXHBQ-D2.5TF | 860 | 810 | 660 | 710 | 315 | 240 | 88 | 70 | 108 |
| RNXHBQ-D3.5TF | 860 | 810 | 660 | 710 | 315 | 240 | 88 | 70 | 108 |
| RNXHBQ-D5TF | 900 | 850 | 750 | 800 | 350 | 290 | 110 | 70 | 145 |
| RNXHBQ-D6TF | 900 | 850 | 750 | 800 | 350 | 290 | 110 | 70 | 158 |
| RNXHBQ-D8TF | 1100 | 930 | 820 | 870 | 400 | 390 | 138 | 70 | 195 |
| RNXHBQ-10TF | 1195 | 1045 | 870 | 920 | 425 | 410 | 148 | 70 | 195 |
H / M / L = high / medium / low speed. Dimension letters match the catalogue drawing. N is the duct connection diameter. Model spelling and all values are kept as printed, including RNXHBQ-10TF and the D6TF cooling-recovery sequence.
WHERE IT WORKS
Applications
The catalogue lists residential rooms, meeting spaces, laboratories, offices, equipment rooms, restaurants and fitness areas. The compact series is relevant when the ventilation requirement can be met by a smaller unit and an appropriate duct layout.
Determine the required fresh air from occupancy and room use, then confirm pressure, noise and access. A compact cabinet should not be selected at the expense of maintenance clearance or the required airflow.
Send Your Requirements →- Apartment or residential ventilation serving a defined room group.
- Small office and meeting-room fresh-air systems.
- Fitness and hospitality spaces with suitable air characteristics.
- Projects with a restricted but serviceable ceiling installation zone.
PROJECT INQUIRY
Discuss This Equipment
Tell us about your equipment requirements and installation conditions.
From cleaner air
to a better future.